VPS2DAY Web Run Tests
Premium - May 06 2022

Go to VPS2DAY



Web Run tests are made of a load test tool and a database intensive Rails web application.

The load test tool sends HTTP requests to the web application at a controlled rate and records HTTP response codes, response latencies and timeouts. The load test tool is multithreaded and runs on the same VPS where the web application runs.

The intent is to measure:

  • the response times (latency) of the web server
  • the amount of CPU used to serve those requests under various load levels
  • what's the maximum load at which 100% requests are served without timing out.

Provider: VPS2DAY
Plan: Premium
Datacenter: Germany
Number of CPU cores: 4
CPU type: AMD EPYC-Rome Processor

Web Runs by request rate


Note: the P99 is the 99th percentile. The P99 latency is the latency of the 1% slowest HTTP requests in the web run.


Rate (reqs/s) Average Latency P99 Latency CPU idle CPU steal Successful requests Timed out requests Duration (minutes)
1 46ms 135ms 97% 0.17% 304 0 5
5 45ms 130ms 92% 0.43% 1504 0 5
10 45ms 130ms 86% 0.76% 6004 0 10
15 44ms 130ms 79% 1.17% 4505 0 5
30 45ms 135ms 63% 1.10% 9014 0 5
50 47ms 145ms 36% 1.14% 15020 0 5
70 47ms 155ms 12% 0.73% 21030 0 5
80 46ms 150ms 3% 0.51% 24037 0 5
90 44ms 145ms 0% 0.23% 25392 1608 5